Best effective tattoo removal q swithced nd yag laser pigmentation removal machine
Application
Tattoo removal, Treatment of Vascular Lesions, Treatment of Pigmented Lesions, Incision, Excision, Ablation, Vaporization of soft Tissue for General Dermatology.
ExQ-Laser™ is newly released Q-Switched Nd:YAG laser therapy system. The system has an optimal clinical treatment effect with following parameter designs:
dual-wavelength switching of 1064nm & 532nm, pulse width short to 5ns and Energy output up to 1000mJ.
Treatment Principle
Treatment principle of Monaliza-2 Q-Switched Nd:YAG Laser Therapy Systems is based on laser selective photothermy and blasting mechanism of Q-Switched laser. Energy form particular wavelength with accurate dose will act on certain targeted color radicals: ink, carbon particles from dema and epidermis, exogenous pigment particles and endogenous melanophore from derma and epidermis. When suddenly being heated, Pigment particles immediately blast into smaller pieces, which will be swallowed by macrophage phagocytosis and enters into lymph circulation system and finally be discharged out of body.
Prominent Advantages
1.Two stages Nd:YAG laser system with electro-optic Q-Switched technology,
which output higher energy. The designs adopt cavity optimized schedule, make
the pulse width as short as 5ns, get doubled output power density under the
same energy.
2. Integrated laser energy monitor system inside, set warning signal when energy
deviation over threshold, all to ensure treatment effectiveness and safety.
3. Seven joints optical articulated arm with adjustable handpiece, spots size
setting from 2 to 10mm. The energy synchronously changes following the
setting spot size.
4. Flat-top beam output, uniformly distributed spot
energy without any heat point, Achieve better
treatment effect and less injuries.
Laser t ype | Q-Switched Nd:YAG | High energy Q-Switched Nd:YAG | ||
Wavelength | 1064nm | 532nm | 1064nm | 532nm |
Pulse width | 5ns | 5ns | 8ns | 8ns |
Pulse energy | 500mJ | 200mJ | 1000mJ | 500mJ |
Pulse energy Range | 200~500mJ | 100~200mJ | 100~1000mJ | 100~500mJ |
Frequency | 5Hz | 5Hz | ||
Spot size | 2~10mm adjustable | 2~10mm adjustable | ||
Fluence | 0.2~16J/cm² | 0.1~6.3J/cm² | 1.3~32J/cm² | 0.6~16J/cm² |
Aiming beam | 635nm,<5mW | |||
Electrical requirements | 110~240VAC 50-60Hz 1200VA | |||
Dimension | 351mmx925mmx775mm(without optical ar ticulated ar m) | |||
Net weight | 80Kg |
Side Effects and Taboos
1. For the darker skin patient, it is not suggestable to randomly adopt high energy because the superficial skin layer pigment’s absorption of laser makesit relatively higher riskif the skin is lightly damaged.
2. The skin may appear red and swollen, skin infiltration of blood and inflammatory reactions after the laser operation. Unguent for scald and scar avoidance shall be used after treatment.
3. For parts of pigments which contains metal ion (such as iron ion), some of dark chemicals (like ferrous oxide), which are difficult to be absorbed after laser treatment, may darker treatment areas. This is caused by different structures of pigments, which has no relations to the device quality.
4. Keep the treatment area dry and clean and protect it from infection.